Insights · November 23, 2026

Building Tier III Data Centers for Power Utilities: Lessons from Bangladesh

By Mohammad Hasan Imam, Executive Vice President, Oculin Tech BD Ltd., and PhD researcher in Computing

When a utility moves to smart metering, its data center stops being a back-office facility. Billing, prepaid vending, meter data management and customer services all depend on it, around the clock. Over the past several years I have led the delivery of turnkey data centers and disaster-recovery (DR) sites for Bangladesh's power distribution utilities, including DESCO, NESCO, DPDC and BREB. These are some of the lessons from that work.

Why Tier III?

The Uptime Institute's Tier III standard requires a facility to be concurrently maintainable: every power and cooling component can be taken out of service for maintenance without shutting down the IT load. For a utility running prepaid metering, that matters. If the vending or head-end platform goes down, customers cannot recharge and meters cannot be managed.

Tier III certification also gives utilities an independent, internationally recognised check that the design and the built facility meet the standard, rather than relying on a contractor's word.

Design for the meter count you will have, not the one you have

Smart-metering programmes grow in phases. BREB's data center, for example, was designed to support up to 5 million smart meters, even though the first contract covered far fewer. The DESCO, NESCO and DPDC facilities were each sized for around 2 million meters. Planning space, power, cooling and network capacity for the end state avoids costly rebuilds a few years later.

Disaster recovery is part of the design, not an add-on

For DESCO, the primary and DR sites were built to identical Tier III standards so that operations can fail over without degraded service. A DR site that is smaller or built to a lower standard often becomes a site nobody trusts enough to use. Key points:

The physical layer matters as much as the IT

Turnkey delivery means owning everything from civil works to the last patch cord: structural and civil design, redundant power with UPS and generators, precision cooling, fire detection and suppression, physical security and cabling. Many failures in practice come from these supporting systems, not from the servers.

A platform built for availability

On the IT side, these facilities combined software-defined networking (Cisco ACI), application delivery and security (F5), enterprise storage (NetApp) and Oracle database and utility platforms (Oracle MDM / C2M). Each layer was designed with redundancy so that a single failure does not interrupt service.

Operations: the NOC and the SLA

A data center is only as good as how it is run. Each facility was paired with a network operations centre (NOC) or command centre for real-time monitoring of utility and IT systems. Running against a contractual service-level agreement (SLA), in our case 99% on mission-critical operations, keeps everyone focused on availability rather than on individual tickets.

Lessons for other utilities

  1. Treat the data center as critical grid infrastructure, with the same reliability expectations as a substation.
  2. Certify to an independent standard such as Uptime Tier III.
  3. Size for the full meter roll-out, and build DR to the same standard as the primary site.
  4. Invest in operations, monitoring and staff training, not only in equipment.